G LAB has undertook technical consultations with amps manufacturers in order to define the way of connecting the G LAB controllers to their amps. As a result there came into existence a list of amps models with defined way of connection and controlling. We would like to thank all the producers thanks to whom there was possible to create this list and we invite other companies to cooperation.
| BRAND | AMP MODELS | TYPE OF CONNECTION |
![[Rozmiar: 5689 bajtów]](/img/logo_blackstar.jpg) | HT-5 | MONO JACK–JACK CABLE » details |
It is possible to control Blackstar HT-5 by GSC-3/GSC-2 (firmware version 2.23 or more).
It is needed to set the switch output mode to SF3 (momentary mode) and use standard MONO JACK–JACK CABLE. |
| SERIES ONE | G LAB ADAPTER Pc:00873
OR STANDARD MIDI CABLE
» details |
It is possible to control Blackstar SERIES ONE by GSC-3/GSC-2 (firmware version 2.23 or more). It is needed to set the switch output mode to SF2 (Pulse Mode). To connect amp with the controller you need G LAB adapter plus original footswitch cable. To select certain amp channel it is needed to program the controller using the rule ‘choose only one from four’. It is also possible to control SERIES ONE amp via MIDI interface. |
| HT VENUE SERIES | G LAB ADAPTER Pc:00873
» details |
It is possible to control Blackstar HT VENUE SERIES by GSC-3/GSC-2 (firmware version 2.25 or more).
It is needed to set the SWITCH output mode:
- SF4 for HT STAGE 60/100 (3 channels (SW1,SW2,SW3) plus momentary REVERB (SW4))
- SF5 for HT SOLOIST (2 channels (SW1,SW2), plus momentary SOLO BOOST (SW3) and momentary REVERB (SW4)
To connect amp with the controller you need G LAB adapter plus original footswitch cable. To select certain amp channel it is needed to program the controller using the rule ‘choose only one from…’.
|
| BONNEVILLE 50, MODENA M60 & M90 | MONO AND STEREO JACK–JACK CABLES » details |
On the back panel of the BONNEVILLE 50, MODENA M60 & M90 amps there are two jack footswitch sockets marked 1 and 2.
For the socket No. 1 (channel switching) use mono Jack–Jack cable and for the socket No. 2 (Boost/Drive and Master1/2 functions) use the stereo Jack-Jack cable. |
| STINGER 30 | STEREO JACK–JACK CABLE » details |
Use stereo Jack–Jack cable to control the channel switching and to turn on/off the FX LOOP.
|
| EL DIABLO 100 | G LAB CABLE » details |
Cable enables to control over the GENZ-BENZ EL DIABLO 100 amp functions (CHANNEL switching, gain, texture, attack). The SW1&2 and SW3&4 marked endings of the cable should be connected to proper outputs of the G LAB GSC or MGC-6 controller. The other DIN type ending should be connected to the amp FOOTSWITCH input. The cable is 5 meters long.
Product code: 00894 |
| ALL MODELS | MONO OR STEREO JACK–JACK CABLE » details |
If the original footswitch cable ends with stereo Jack connector then it is needed to use standard stereo JACK–JACK cable and if it ends with mono Jack connector use the mono JACK–JACK cable. |
| ALL MODELS | G LAB CABLE Pc:00847 STEREO JACK–JACK OR STANDARD MIDI CABLE » details |
To control Studiotone, Studiotone XL, Twintone I amps you should connect the G LAB controller switch outputs (SW1&2 or/and SW3&4) with the footswitch inputs using standard stereo JACK–JACK cable.
Use G LAB CABLE (Pc:00847) to control Twintone II, Multitone (I&II), Powertone (I&II) amps. The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other not marked ending should be connected to the amp FOOTSWITCH input.
To control SuperNova amp use standard MIDI interface.
|
| ALL MODELS
| MONO AND STEREO JACK–JACK CABLES » details |
If the original footswitch cable ends with stereo Jack connector then it is needed to use standard stereo JACK–JACK cable and if it ends with mono Jack connector use the mono JACK–JACK cable. |
| MP 101 | MONO JACK–JACK CABLE » details |
Use mono Jack–Jack ¼” to control amp channel switching.
|
| CS 40 | STEREO JACK–JACK CABLE
» details |
Use stereo Jack–Jack cable ¼” to control the BOOST and to switch between TUBE and FET. |
 | ALL MODELS | MONO JACK–JACK
OR "Y" TYPE CABLES » details |
To control the amp you should connect the G LAB controller switch outputs (SW1&2 or/and SW3&4) with the footswitch inputs using standard mono JACK–JACK cables or Y type cable (stereo Jack - 2 x mono Jack).
The orange amps connect as follows:
AD30TC and HTC = 1 x latching foot switch jack (Mono)
Rocker 30 = 1 x latching foot switch jack (Mono)
Dual Terror = 1 x latching foot switch jack (Mono)
Rockerverb 50 and 100 = 2 x latching foot switch jack (Mono)
Thunderverb 50 and 200 = 3 x latching foot switch jack (Mono) |
As a result of cooperation with our customers we present the list of G LAB cables and adapters which enable to control amps by G LAB controller.
| BRAND | AMP MODELS | TYPE OF CONNECTION |
| BOGNER |
ECSTASY 101 B | MAC-4.4 for BOGNER ECSTASY 101B AMP
|
| ALCHEMIST | G LAB CABLE
» details |
The Cable enables to control over the BOGNER ALCHEMIST functions (SELECT CHANNEL, BOOST, DELAY, REVERB). The SW1&2 and SW3&4 marked endings of the cable should be connected to proper outputs of the G LAB GSC or MGC-6 controller. The other XLR type ending should be connected to the FOOTSWITCH amp input. Power supply connector should be connected to 9V DC power source (e.g. to one of the GSC-2 or GSC-3 9V DC power supply connector). Power consumption is 40mA.
Product code: 00875
|
| CERIATONE | HRM-50 | G LAB CABLE
» details |
Cable enables to control over the CERIATONE HRM-50 amp functions (CHANNEL switching, BOOST). The SW1&2 marked ending of the cable should be connected to the proper output of the G LAB GSC or MGC-6 controller. The other DIN type ending should be connected to the amp FOOT PEDAL input. The cable is 5 meters long.
There are two types of the cables available:
1. With 180 degree DIN plug (Product code: 00885)
2. With 240 degree DIN plug (Product code: 00888)
|
| EGNATER | TOURMASTER: TM 4100, TM 4212 | G LAB ADAPTER
» details |
Adapter enables to control over the EGNATER TOURMASTER TM 4100 and TM 4212 amp functions (CHANNEL switching, REVERB and turning ON/OFF effect loop). The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original FOOTSWITCH cable to the amp FOOTSWITCH input.
Product code: 00858 |
| EVH | 5150 III | G LAB ADAPTER
» details |
Adapter enables to control over the EVH 5150 III amp functions (CHANNEL switching and turning ON/OFF effect loop). The SW1&2 and SW3&4 marked endings of the adapter should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter’s connector should be connected with the original FOOTSWITCH cable to the amp FOOTSWITCH input.
Product code: 00891 |
| FENDER | CONCERT '81, '83 SUPER CHAMP TWIN REVERB II FENDER 75 | G LAB CABLE
» details |
The cable enables to control LEAD and REVERB functions of the FENDER amps:
- CONCERT '81, '83,
- SUPER CHAMP,
- TWIN REVERB II,
- FENDER 75.
The ending of the cable marked with SW1&2 should be connected to proper output of the G LAB GSC or MGC-6 controller and the other not marked ending should be connected to the FOOTSWITCH amp input.
Product code: 00892 |
Hot Rod Deluxe Hot Rod DeVille 410, 212 FM 100 Head, FM 212R | PRZEWÓD G LAB
» details |
The cable enables to control over FENDER branded amps:
- Hot Rod Deluxe,
- Hot Rod DeVille 410,
- Hot Rod DeVille 212,
- FM 100 Head,
- FM 212R.
This cable can be used also with other amps controlled by the 2-button 3-function footswitch (controls Channel, Gain and More Gain functions), FENDER product No.: 0994062000.
The SW1&2 marked ending of the cable should be connected to SW1&2 or SW3&4 outputs of the controller and the other ending not marked should be connected to the FOOTSWITCH amp input.
The work status indicating panel (yellow indicator is lit constantly, when red one besides is lit – More Gain, when red one external is lit – channel overdriven).
Product code: 00803
|
| SUPER-SONIC | G LAB CABLE
» details |
The cable enables to control over the FENDER SUPER-SONIC amp functions (modes: BASSMAN, VIBROLUX, BURN, VINTAGE; the loop effect of the amp is permanently ON).
The SW1&2 marked ending of the cable should be connected to SW1&2 or SW3&4 outputs of the G LAB controller and the other ending not marked should be connected to the FOOTSWITCH amp input.
Product code: 00839
|
| TWIN-AMP | G LAB CABLE
» details |
The cable enables to control over the FENDER TWIN-AMP functions (modes: CHANNEL SELECT, GAIN SELECT, REVERB).
The endings of the cable marked with SW1&2 and SW3&4 should be connected to proper outputs of the G LAB GSC or MGC-6 controller and the other not marked ending should be connected to the FOOTSWITCH amp input.
Product code: 00887
|
FRYETTE (Pre 2009 VHT) | PITBULL CL | G LAB CABLE
» details |
The Cable enables to control over the FRYETTE (Pre 2009 VHT) PITBULL CL 50 and 100 series functions (CHANNEL, BOOST, EFFECTS, EQ). The SW1&2 and SW3&4 marked endings of the cable should be connected to proper outputs of the G LAB GSC or MGC-6 controller. The other DIN type ending should be connected to the FOOTSWITCH amp input. The cable is 5 meters long.
Product code: 00881 |
| HUGHES & KETTNER | DUOTONE
| G LAB CABLE
» details |
The Cable enables to control over the HUGHES & KETTNER DUOTONE functions (CHANNEL, BOOST, MASTER ). The SW1&2 and SW3&4 marked endings of the cable should be connected to proper outputs of the G LAB GSC or MGC-6 controller. The other XLR type ending should be connected to the FOOTSWITCH amp input. The cable is 5 meters long.
Product code: 00884 |
| LANEY | VH 100R | G LAB ADAPTER
» details |
Adapter enables to control over the LANEY VH 100R amp functions (DRIVE A, DRIVE B, REVERB, CHANNEL B). The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original FOOTSWITCH cable to the amp FOOTSWITCH input.
Product code: 00864 |
| MARSHALL | TSL series (60, 601, 602, 100, 122) | G LAB CABLE
» details |
The Cable enables to control over the MARSHALL TSL functions (CHANNEL SWITCHING, REVERB and EFFECT)
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other (DIN type) ending not marked should be connected to the FOOTSWITCH amp input.
Product code: 00830 |
MODE FOUR MF 350 AVT (150X, 150HX, 275X) | G LAB ADAPTER
» details |
These amps are designed to be controlled by 6 function PEDL-00032 footswitch equipped with DSUB 15 socket. MA32 Adapter enables to control over the MARSHALL MF350 with PEDL-10032 functions (CLEAN, CRUNCH, OD1, OD2, SOLO and REVERB) and MARSHALL AVT series with PEDL-10031 (ACO. SIM., CLEAN, OD1, OD2, DFX SIM/CLEAN, DFX OD1/2)
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original FOOTSWITCH cable to the FOOTSWITCH amp input.
Product code: 00824 |
| VALVESTATE VS265 | G LAB CABLE
» details |
The Cable enables to control over the MARSHALL VALVESTATE VS265 functions (Cln/Ovd, Ovd1/Ovd2, Chorus On/Off).
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other (DIN type) ending not marked should be connected to the FOOTSWITCH amp input.
Product code: 00874 |
| MESA BOOGIE | ALL MODELS WITH EXTERNAL SWITCHING INPUTS | MAC-4.4 for MESA BOOGIE AMPS
|
| F-Series | G LAB ADAPTER
» details |
Adapter enables to control over the Mesa/Boogie F-30, F-50, F-100 amps functions (CHANNEL, CONTOUR, REVERB).
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original footswitch cable to the FOOTSWITCH amp input.
Product code: 00880 |
| PEAVEY | JSX
| G LAB CABLE
» details |
The Cable enables to control over the PEAVEY JSX functions (channel switching and switch ON/OFF effect loop of the amp). Controller gives a possibility to control PEAVEYs functions pressing only one footswitch in contradiction to original foot pedal – using up to three footswitches.
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other ending not marked should be connected to the REMOTE SWITCH SOCKET amp input.
Product code: 00835 |
| TRIPLE XXX | G LAB ADAPTER
» details |
Adapter enables to control over the PEAVEY TRIPLE XXX function (channel switching CLEAN, CRUNCH, ULTRA and turning ON/OFF effect loop).
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original FOOTSWITCH cable to the FOOTSWITCH amp input.
Product code: 00849 |
| RANDALL | RG100SC (G2) and RH200SC (G2) amps
| G LAB ADAPTER
» details |
Adapter enables to control over the RANDALL RG 100 SC or RH 200 SC amp functions (CHANNEL, REVERB, CHORUS and GAIN 1/ GAIN 2, CLEEN/BOOST modes).
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other adapter ending should be connected through the original FOOTSWITCH cable to the FOOTSWITCH amp input.
Product code: 00851 |
| RH150G3 | G LAB CABLE
» details |
The cable enables to control over the RANDALL RH150G3 amp with DIN type socket. This cable controls CHANNEL, GAIN, CLEAN BOOST and REVERB/EFFECT functions.
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the DIN ending should be connected to the FOOTSWITCH amp input.
Product code: 00818 |
| RIVERA | Amp models with FS-7 footswitch | G LAB CABLE
» details |
The cable enables to control over the RIVERA (R/K/RAKE models) amp with FS-7 footswitch. The cable controls CHANNEL SWITCHING, BOOST and NINJA BOOST functions.
The SW1&2 and SW3&4 marked endings of the cable should be connected to SW1&2 and SW3&4 outputs of the controller and the other ending not marked should be connected to the FOOTSWITCH amp input.
In case of using other amp model should be checked in the amp’s documentation if it is controlled by FS-7 footswitch.
Product code: 00817 |
| TRACE ELLIOT | TRIDENT | MAC-4.4 FOR TRACE ELLIOT TRIDENT AMP
|
A lot of amps are equipped with Jack type footswitch input so if your amp is equipped with such type connector you should contact your dealer or the manufacturer of your amp to settle if it is possible to connect directly (with mono or stereo Jack/Jack or Y type cable ) using relay outputs.